Radiology

Dry Pix Smart

Back

The most advanced DRYPIX has arrived, assisting smooth diagnoses.
Despite its compact size, enabling use anywhere in a medical facility, throughput is extremely high with no compromise on image quality.


Product detail of Dry Pix Smart

FCR Capsula XL II Overview


FCR PRIMA II is one of the most compact and lightweight reader units on the market. The required space is comparatively smaller than other similar table-top systems and can be installed in any open space. Another advantage of this unit is that you don't need a darkroom any longer.

The new model FCR PRIMA II now offers enhanced processability with speed of up to 55 IPS/hr., almost double FCR PRIMA's 29 IPS/hr., yet leaving the easy operability and high functionality intact. As a result, the patient handling time at clinics and hospitals is reduced significantly leading to smoother operation and increased patient turnover.

FCR PRIMA Console and FCRView are an all-in-one viewers that turns your desktop into a multi-function workstation for all your radiographic imaging needs. You can initiate exposures, process and print your studies and backup patient information all within a single unit.

Compact footprint, only 0.24 m²


FCR PRIMA II is one of the most compact and lightweight reader units on the market. The required space is comparatively smaller than other similar table-top systems and can be installed in any open space. Another advantage of this unit is that you don't need a darkroom any longer.

Enhanced IP processability


The new model FCR PRIMA II now offers enhanced processability with speed of up to 55 IPS/hr., almost double FCR PRIMA's 29 IPS/hr., yet leaving the easy operability and high functionality intact. As a result, the patient handling time at clinics and hospitals is reduced significantly leading to smoother operation and increased patient turnover.

Stable high-quality images


Although this is a compact machine its excellent image quality is the same as that produced by the rest of the FCR range. Image Intelligence™, Fujifilm's proprietary image processing technology, enhances image contrast and sharpness, without any deterioration of details. FCR PRIMA T supports accurate diagnosis by offering stable and optimized image quality.

MFP (Multi-Frequency Processing)*
Enhances FCR images. All diagnostic scopes will be enhanced except for noise. * Optional Software

FNC (Flexible Noise Control)
Provides a non-grainy image by mainly isolating and suppressing the noise for the signal.

MFP (Multi-Frequency Processing)* Enhances FCR images. All diagnostic scopes will be enhanced except for noise. * Optional Software

System Configuration


All-in-one workstation


FCR PRIMA Console and FCRView are an all-in-one viewers that turns your desktop into a multi-function workstation for all your radiographic imaging needs. You can initiate exposures, process and print your studies and backup patient information all within a single unit.

Specifications


Standard Components FCR CAPSULA XLII Image Reader Unit (Model: CR-IR 359)
AC power cord
Other System Components Optional upgrade kit for 50-micron reading with HR-V or HR-VI
IP cassette type CC, LC, CH
CR Console, CONSOLE ADVANCE*, AWS-c
Dry Imager: DRYPIX 2000, 4000, 7000
Supplies
Imaging Plate:
  • ST-VI: 35 × 43 cm (14″ × 17″), 35 × 35 cm (14″ × 14″),
    10″ × 12″, 8″ × 10″, 24 × 30 cm, 18 × 24 cm, 15 × 30 cm
  • HR-V: 24 × 30 cm**, 18 × 24 cm***
  • HR-VI: 24 × 30 cm**, 18 × 24 cm***
IP Cassette:
  • Type CC: 35 × 43 cm (14″ × 17″), 35 × 35 cm (14″ × 14″),
    10″ × 12″, 8″ × 10″, 24 × 30 cm, 18 × 24 cm, 15 × 30 cm
  • Type LC: 35.4 × 124.5 cm, 35.4 × 101.7 cm, 35.4 × 83.7 cm,
    25.2 × 58 cm, 24 × 57 cm
  • Type CH: 24 × 30 cm**, 18 × 24 cm***
    (For 50-micron reading with HR-V or HR-VI)
Number of Stacker 1
Reading Gray Scale 12 bits
Network 10 Base T / 100 Base TX
Dimensions (W × D × H) 590 × 380 × 810 mm (23″ × 15″ × 32″)
[Image] Dimensions / Imaging Plate ST-VI / IP Cassette Type CC
Weight 99 kg (218 lbs.)
Power Supply Conditions Single phase 50 - 60 Hz
AC 120 - 240 V ±10% 5 A (max)
Environmental Conditions
Operating Conditions:
  • Temperature: 15 - 30 °C
  • Humidity: 40 - 80 % RH (No dew condensation)
Non-operating Conditions:
  • Temperature: 0-45 °C
  • Humidity: 10 - 90 % RH (No dew condensation)
  • Under "Required Time” in the table above, figures in parentheses are at high-speed mode.
  • Image erase time on IP is directly related to the exposure made. It is assumed to be at 25 mR for ST-VI and 600 mR for HR-V.
  • The performance described above shows typical values. It varies depending on the exposure level.

Processing Capacity


IP Type Required Time
ST-VI 35 × 43 cm (14″ × 17″) Approx. 58 (41) sec.
ST-VI 35 × 35cm (14″ × 14″) Approx. 52 (38) sec.
ST-VI 10″ × 12″ Approx. 49 sec.
ST-VI 8″ × 10″ Approx. 41 sec.
ST-VI 24 × 30 cm Approx. 48 sec.
ST-VI 18 × 24 cm Approx. 39 sec.
ST-VI 15 × 30 cm Approx. 49 sec.
HR-V 24 × 30 cm** Approx. 59 sec.
HR-V 18 × 24 cm*** Approx. 51 sec.
HR-VI 24 × 30 cm** Approx. 59 sec.
HR-VI 18 × 24 cm*** Approx. 51 sec.
  • Figures in parentheses and conditions are the same as those of “Time Required for IP Feed / Load".
  • The time required to change the cassette is assumed to be 0 (zero) seconds.

Time to Display on CR Console:


  • Approx. 42 sec. in case of 35 × 43 cm (ST-VI) with 100-micron reading
  • Approx. 32 sec. in case of 18 × 24 cm (HR-V)*** with 50-micron reading

Time to Print on DRYPIX 4000 through network via CR Console:


  • Approx. 145 sec. in case of 35 × 43 cm (ST-VI) with 100-micron reading
  • Approx. 140 sec. in case of 18 × 24 cm (HR-V)*** with 50-micron reading

Reading Specification


Inches Metric Reading Specification
Standard Pixel-density High Pixel-density
High-speed mode Standard mode
14″ × 17″ (ST-VI) 35 × 43 cm (ST-VI) 5 pixels / mm 10 pixels / mm
14″ × 14″ (ST-VI) 35 × 35 cm (ST-VI) 5 pixels / mm 10 pixels / mm
10″ × 12″ (ST-VI) 24 × 30 cm (ST-VI) 10 pixels / mm
8″ × 10″ (ST-VI) 18 × 24 cm (ST-VI) 10 pixels / mm
15 × 30 cm (ST-VI) 10 pixels / mm
24 × 30 cm (HR-V)** 20 pixels / mm
18 × 24 cm (HR-V)*** 20 pixels / mm
24 × 30 cm (HR-VI)** 20 pixels / mm
18 × 24 cm (HR-VI)*** 20 pixels / mm

IP Cassette


  • Approx. 145 sec. in case of 35 × 43 cm (ST-VI) with 100-micron reading
  • Approx. 140 sec. in case of 18 × 24 cm (HR-V)*** with 50-micron reading

IP Cassette